Generators

 

50 Hz  Deutz / Leroy Somer

 
 
Model Standby Power Prime Power  Engine Alternator
KVA / KW  KVA/KW  Make Model Make Model
 
M-F35 specification
M-F35 35 28 30 24 DEUTZ F4L912 Leroy Somer LSA42.2L9
M-F55 specification
M-F55 55 44 48 38 DEUTZ F4L912T Leroy Somer LSA43.2S35
 
1. Brand new Joint Venture DEUTZ engine.
2. Brand new Leroy Somer AC alternator, Ratings: 230/400v, 3Ph, 50Hz, 1500Rpm, 0.8PF, IP23, H insulation class.
3. Standard Radiator mounted on skid.
4. AC/DC control panel consisting of:  Emergency Stop button,  Voltmeter and selector switch, Ammeter and selector switch, Frequency meter, Oil pressure gauge, Water Temperature gauge, Controller DKG507 with following (and not restricted to) features: Remote Control, AMF, Function record, Start/Stop button, Hour run display, High engine temperature shutdown protection, Low oil pressure shutdown protection, Over speed shutdown protection, Alarm output for abnormal operation .
5. Circuit breaker/&battery charger.
6.Anti-Vibration elements between engine/alternator and base frame.
7. 24V lead acid battery and battery leads.
8.Silencers with flanged flexible connection.
9. Open type Genset below 200kw&All silent type genset will be with a base fuel tank for at least 8 hours running, with fuel gauge integrated in the base frame.
10. English operation/maintenance manuals/test report for engine, alternator and genset.
11.Standard tools kit.
 
   
 

50 Hz Cummins / Leroy Somer

 
 
Model Standby Power Prime Power  Engine Alternator
KVA / KW  KVA/KW  Make Model Make Model
 
   
M-C30 specification
M-C30 30 24 27.5 22 Cummins 4B3.9G2 Leroy Somer LSA42.2M7
 
M-C50 specification
M-C50 50 40 45 36 Cummins 4BTA3.9G2 Leroy Somer LSA43.2S25
 
M-C70 70 56 63 50 Cummins 4BT3.9-G2 Leroy Somer LSA43.2L65
 
M-C100 specification
M-C100 100 80 90 72 Cummins 6BT5.9G1 Leroy Somer LSA44.2VS3
 
M-C110 110 88 100 80 Cummins 6BT5.9-G2 Leroy Somer LSA44.2VS45
 
M-C138 specification
M-C138 138 110 125 100 Cummins 6BTAA.9G2 Leroy Somer LSA44.2S7
 
M-C163 163 130 150 120 Cummins 6CTA8.3G2 Leroy Somer LSA44.2M95
 
M-C206 specification
M-C206 206 165 188 150 Cummins 6CTA8.3G2 Leroy Somer LSA46.2M3
 
M-C215 215 172 200 160 Cummins 6CTAA8.3G2 Leroy Somer LSA46.2M5
 
M-C275 specification
M-C275 275 220 250 200 Cummins 6LTAA8.9G2 Leroy Somer LSA46.2L6
 
M-C313 313 250 275 220 Cummins NTA855G1A Leroy Somer LSA46.2L9
 
M-C350 specification
M-C350 350 280 313 250 Cummins NTA855G1B Leroy Somer LSA46.2VL12
 
M-C388 388 310 350 280 Cummins NTA855G2A Leroy Somer LSA47.2VS2
 
 
M-C413 413 330 375 300 Cummins NTAA855G7 Leroy Somer LSA47.2VS2
 
 
M-C450 450 360 413 330 Cummins NTAA855G7A Leroy Somer LSA47.2S4
 
 
M-C500 500 400 450 360 Cummins KTA19G3 Leroy Somer LSA47.2S5
 
 
M-C550 550 440 500 400 Cummins KTA19G4 Leroy Somer LSA47.2M7
 
 
M-C600 600 480 550 440 Cummins KTAA19G5 Leroy Somer LSA47.2M8
 
 
M-C625 625 500 563 460 Cummins KTAA19G5 Leroy Somer LSA47.2L9
 
 
M-C650 625 500 563 460 Cummins KTAA19G6 Leroy Somer LSA47.2L9
 
 
M-C688 688 550 625 500 Cummins KTAA19G6A Leroy Somer LSA49.1S4A
 
 
M-C825 825 660 750 600 Cummins KTA38-G2 Leroy Somer LSA49.1M65 
 
 
M-C900 900 720 800 640 Cummins KTA38-G2A Leroy Somer LSA49.1M75
 
 
M-C1000 1000 800 900 720 Cummins KTA38-G2A Leroy Somer LSA49.1L10
 
 
M-C1100 1100 880 1000 800 Cummins KTA38-G5 Leroy Somer LSG55
 
  All Generators come with:
1. Brand new Joint Venture Cummins engine.
2. Brand new Leroy Somer AC alternator, Ratings: 230/400v, 3Ph, 50Hz, 1500Rpm, 0.8PF, IP23, H insulation class.
3. Standard Radiator mounted on skid.
4. AC/DC control panel consisting of:  Emergency Stop button,  Voltmeter and selector switch, Ammeter and selector switch, Frequency meter, Oil pressure gauge, Water Temperature gauge, Controller DSE702 with following (and not restricted to) features: Start/Stop button, Hour run display, High engine temperature shutdown protection, Low oil pressure shutdown protection, Over speed shutdown protection, Alarm output for abnormal operation .
5. Circuit breaker/&battery charger.
6.Anti-Vibration elements between engine/alternator and base frame.
7. 24V lead acid battery and battery leads.
8.Silencers with flanged flexible connection.
9. Open type Genset below 200kw & All silent type genset will be with a base fuel tank for at least 8 hours operation, with fuel gauge integrated in the base frame.
10. English operation/maintenance manuals/test report for engine, alternator and genset.
11.Standard tools kit.
 
 Note: Gensets below 200KW/250KVA come with a base fuel tank for 8 hours operation. Gensets larger than 200KW/250KVA have optional base fuel tank available.  
 
Model Standby Power Prime Power  Engine Alternator
KVA / KW  KVA/KW  Make Model Make Model
 
Sound Proof Enclosure Robust/Highly Corrosion Resistant Construction
Excellent Access for Maintenance
Security and Safety
Transportability
 

Parts ,Service, Push Packs

 
 

Intercon Modular, LLC
contact:
 richard.hill@inter-con.us
www.inter-con.us
+1-801-705-4567
(f) +1-801-221-2587