Intercon Modular, LLC +1 801-225-1180

Generators

50 Hz Deutz / Leroy Somer

ModelStandby powerPrime powerEngineAlternatorSpec sheet
kVAkWkVAkWMakeModelMakeModel
M-F3535283024DEUTZF4L912Leroy SomerLSA42.2L9PDF
M-F5555444838DEUTZF4L912TLeroy SomerLSA43.2S35PDF
Standard equipment (Deutz)
  1. Brand new Joint Venture DEUTZ engine.
  2. Brand new Leroy Somer AC alternator. Ratings: 230/400 V, 3 Ph, 50 Hz, 1500 rpm, 0.8 PF, IP23, H insulation class.
  3. Standard radiator mounted on skid.
  4. AC/DC control panel consisting of: emergency stop button, voltmeter and selector switch, ammeter and selector switch, frequency meter, oil pressure gauge, water temperature gauge, controller DKG507 with following (and not restricted to) features: remote control, AMF, function record, start/stop button, hour run display, high engine temperature shutdown protection, low oil pressure shutdown protection, over speed shutdown protection, alarm output for abnormal operation.
  5. Circuit breaker & battery charger.
  6. Anti-vibration elements between engine/alternator and base frame.
  7. 24 V lead acid battery and battery leads.
  8. Silencers with flanged flexible connection.
  9. Open type gensets below 200 kW and all silent type gensets come with a base fuel tank for at least 8 hours running, with fuel gauge integrated in the base frame.
  10. English operation/maintenance manuals/test report for engine, alternator and genset.
  11. Standard tools kit.

50 Hz Cummins / Leroy Somer

ModelStandby powerPrime powerEngineAlternatorSpec sheet
kVAkWkVAkWMakeModelMakeModel
M-C30302427.522Cummins4B3.9G2Leroy SomerLSA42.2M7PDF
M-C5050404536Cummins4BTA3.9G2Leroy SomerLSA43.2S25PDF
M-C7070566350Cummins4BT3.9-G2Leroy SomerLSA43.2L65–
M-C100100809072Cummins6BT5.9G1Leroy SomerLSA44.2VS3PDF
M-C1101108810080Cummins6BT5.9-G2Leroy SomerLSA44.2VS45–
M-C138138110125100Cummins6BTAA.9G2Leroy SomerLSA44.2S7PDF
M-C163163130150120Cummins6CTA8.3G2Leroy SomerLSA44.2M95–
M-C206206165188150Cummins6CTA8.3G2Leroy SomerLSA46.2M3PDF
M-C215215172200160Cummins6CTAA8.3G2Leroy SomerLSA46.2M5–
M-C275275220250200Cummins6LTAA8.9G2Leroy SomerLSA46.2L6PDF
M-C313313250275220CumminsNTA855G1ALeroy SomerLSA46.2L9–
M-C350350280313250CumminsNTA855G1BLeroy SomerLSA46.2VL12PDF
M-C388388310350280CumminsNTA855G2ALeroy SomerLSA47.2VS2–
M-C413413330375300CumminsNTAA855G7Leroy SomerLSA47.2VS2–
M-C450450360413330CumminsNTAA855G7ALeroy SomerLSA47.2S4–
M-C500500400450360CumminsKTA19G3Leroy SomerLSA47.2S5–
M-C550550440500400CumminsKTA19G4Leroy SomerLSA47.2M7–
M-C600600480550440CumminsKTAA19G5Leroy SomerLSA47.2M8–
M-C625625500563460CumminsKTAA19G5Leroy SomerLSA47.2L9–
M-C650Contact us for specifications–
M-C688688550625500CumminsKTAA19G6ALeroy SomerLSA49.1S4A–
M-C825825660750600CumminsKTA38-G2Leroy SomerLSA49.1M65–
M-C900900720800640CumminsKTA38-G2ALeroy SomerLSA49.1M75–
M-C10001000800900720CumminsKTA38-G2ALeroy SomerLSA49.1L10–
M-C110011008801000800CumminsKTA38-G5Leroy SomerLSG55–
All Cummins generators come with
  1. Brand new Joint Venture Cummins engine.
  2. Brand new Leroy Somer AC alternator. Ratings: 230/400 V, 3 Ph, 50 Hz, 1500 rpm, 0.8 PF, IP23, H insulation class.
  3. Standard radiator mounted on skid.
  4. AC/DC control panel consisting of: emergency stop button, voltmeter and selector switch, ammeter and selector switch, frequency meter, oil pressure gauge, water temperature gauge, controller DSE702 with following (and not restricted to) features: start/stop button, hour run display, high engine temperature shutdown protection, low oil pressure shutdown protection, over speed shutdown protection, alarm output for abnormal operation.
  5. Circuit breaker & battery charger.
  6. Anti-vibration elements between engine/alternator and base frame.
  7. 24 V lead acid battery and battery leads.
  8. Silencers with flanged flexible connection.
  9. Open type gensets below 200 kW and all silent type gensets come with a base fuel tank for at least 8 hours running, with fuel gauge integrated in the base frame.
  10. English operation/maintenance manuals/test report for engine, alternator and genset.
  11. Standard tools kit.

Note: gensets below 200 kW/250 kVA come with a base fuel tank for 8 hours operation. Gensets larger than 200 kW/250 kVA have an optional base fuel tank available.

Sound Proof Enclosure

  • Robust / highly corrosion resistant construction
  • Excellent access for maintenance
  • Security and safety
  • Transportability

📄 Sound Proof Enclosure (PDF)

Parts, service & push packs →

Generator quotes

Call +1 801-225-1180 · fax +1-801-221-2587 · richard.hill@inter-con.us